Equilibrium field coils
Contents
Also called the poloidal field coils when excluding the toroidal field (TF) and ohmic heating (OH) coils, this is the set of electromagnets used to confine, control, and shape LTX plasmas. As in any tokamak, the TF coils provide a strong guide field along which the plasma can flow freely; the OH coil drives toroidal plasma current to compensate for the grad-B and curvature drifts in the toroidal field; a Helmholtz coil (blue coil) sets up a vertical field to compensate the tire and current-loop forces pushing the plasma outward radially. The remaining coils provide vertical and radial stability, eddy current and field null compensation, and poloidal cross-section shaping.
More details of equilibrium coil design (number of windings, conductor cross section, etc.) can be found in this document.
Simple model of OH circuit: https://www.circuitlab.com/circuit/6sg6ae9zmf89/ltx-oh/
Coil Parameters
| Color | Purpose | Power Supply | Waveform source | Coil radius (R) | Coil height (Z) | Inductance | Resistance |
|---|---|---|---|---|---|---|---|
| Toroidal Field | Robicon T1+PEI | Chronos AO-06 | ~0.75m | U: ~0.7m L: ~-0.7m |
5600μH | 148mΩ | |
| Ohmic Heating (OH) | OH cap bank (OH cap room) |
OH Controller VI | OH1 (N=74): 0.0747m OH2U(N=2): 0.513m OH2L(N=2): 0.513m OH3U(N=2): 0.154m OH3L(N=2): 0.154m |
OH1 (N=74): -0.534m...0.534m OH2U(N=2): 1.02m OH2L(N=2): -1.02m OH3U(N=2): 0.511m OH3L(N=2): -0.511m |
113μH | 7.81mΩ | |
| Blue | Vertical Field | Robicon IF | Chronos AO-01 | U: 0.862m L: 0.862m |
U: 0.406m L: -0.413m |
U: 337μH L: 333μH |
U: 5.2mΩ L: 5.2mΩ |
| Red | Shaping | Robicon DF | Chronos AO-05 | U: 0.673m L: 0.673m |
U: 0.494m L: -0.497m |
U: 147μH L: 142μH |
U: 11.8mΩ L: 11.7mΩ |
| Orange | Field curvature | Robicon T3 | Chronos AO-03 | U: 0.3923m L: 0.3923m |
U: 0.8240 L: -0.8240m |
U: 520μH L: 520μH |
U: 20.75mΩ L: 20.75mΩ |
| Yellow | VF Null | Yellow cap bank (L210 N wall) |
RLC Circuit | U: 0.724m L: 0.730m |
U: 0.800m L: -0.787m |
U: 12.8μH L: 12.28μH |
U: 0.96mΩ L: 0.96mΩ |
| Green | OH Eddy Cancellation | Robicon T4 | Chronos AO-04 | U: 0.100m L: 0.094m |
U: 0.486m L: -0.490m |
U: 300μH L: 300μH |
U: 24mΩ L: 24mΩ |
| Internal | Active Feedback | Robicon T2 | Chronos AO-02 | U: 0.632m L: 0.632m |
U: 0.367m L: -0.367m |
U: 35μH L: 35μH |
U: 2.1mΩ L: 2.1mΩ |
Related Pages
Coil current monitors - lists current monitor diagnostics and their integrator and digitizer channels.
Measurement conventions: Currents, Fields, and Flows - lists the relative directions of currents in equilibrium field coils.
Power supplies - details on the power supplies for the field coils.