| Conductor width |
m |
0.0500 |
|
Conductor width |
m |
0.0500 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Conductor height |
m |
0.1000 |
|
Conductor height |
m |
0.1000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Aspect ratio |
|
2.0 |
|
Cooling hole diameter |
m |
0.0175 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cooling hole diameter |
m |
0.0175 |
|
Max length of single conductor section |
m |
5.9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cooling hole diameter |
in |
0.6890 |
|
Current |
Amp rms |
15000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Conductor area |
m2 |
0.0048 |
|
Avg conductor length per pole |
m |
30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| #Conductor in parallel electrically and
hydraulically per pole |
|
2 |
|
#Conductor in parallel electrically and hydraulically per pole |
|
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| #Poles in series hydraulically |
|
2 |
|
Resistance per pole at 20C |
mOhm |
0.055 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Total length per pole pair |
m |
657 |
|
Flow velocity |
m/s |
2.8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Number of pole pairs |
|
27 |
|
Flow per conductor |
m3/s |
6.69E-04 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Shaft to chimney allowance |
m |
6 |
|
Mass flow per conductor |
kg/s |
0.66 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Avg conductor length per pole |
m |
30 |
|
#Poles in series hydraulically |
|
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| fraction cooling hole dia / min(width, height) |
|
0.3500 |
|
Hydraulic path delta_P |
MPA |
0.25 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fraction allowable |
|
0.3750 |
|
Return pressure |
MPA |
0.02 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Current |
Amp rms |
15000 |
|
Inlet pressure |
MPA |
0.38 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Flow velocity |
feet/sec |
9.12 |
|
Water Inlet Temperature |
deg C |
45 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Flow velocity |
m/s |
2.8 |
|
Water delta_T |
deg C |
5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Allowable flow velocity |
m/s |
4.0 |
|
Resistance per pole at average temperature |
mOhm |
0.061 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cooling hole area |
m2 |
2.41E-04 |
|
Ohmic dissipation per pole |
kW |
14 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Flow per conductor |
m3/s |
6.69E-04 |
|
Ohmic dissipation per unit length |
kW/m |
0.45 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Flow per conductor |
GPM |
10.60 |
|
Total # bus bar poles |
|
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Mass flow per conductor |
kg/s |
0.66 |
|
Total ohmic dissipation, fraction of total coil + bus bar |
|
0.05 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water Inlet Temperature |
deg C |
45 |
|
Total flow |
m3/s |
2.67E-03 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Allowable Water Outlet Temperature |
deg C |
50 |
|
Total mass flow |
kg/s |
2.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water Average Temperature |
deg C |
48 |
|
Total bus bar resistance at 20C |
ohm |
1.10E-04 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cs0 |
|
4229.2 |
|
Total bus bar resistance at average temperature |
ohm |
1.22E-04 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cs1 |
|
-3.857 |
|
Total coil resistance at 20C |
ohm |
1.85E-03 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cs2 |
|
0.06786 |
|
Total coil resistance at average temperature |
ohm |
2.50E-03 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cs3 |
|
-0.0003745 |
|
Total circuit resistance at 20C |
ohm |
1.96E-03 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cs4 |
|
8.19E-07 |
|
Total circuit resistance at average temperature |
ohm |
2.62E-03 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Specific Heat |
J/kg-C |
4.16E+03 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cv0 |
|
0.0017887 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cv1 |
|
-5.13E-05 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cv2 |
|
7.91E-07 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cv3 |
|
-6.75E-09 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cv4 |
|
3.16E-11 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cv5 |
|
-7.54E-14 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cv6 |
|
7.17E-17 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water Dynamic Viscosity |
kG/m-s |
5.58E-04 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cd0 |
|
998.0853301 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cd1 |
|
-0.061254033 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| cd2 |
|
-0.003076198 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water Density |
kg/m3 |
9.88E+02 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water Kinematic Viscosity |
m2/s |
5.65E-07 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water Reynold's Number |
|
8.61E+04 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water Friction Factor |
|
1.85E-02 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Hydraulic path delta_P |
PA |
2.47E+05 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Hydraulic path delta_P |
psi |
36 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Plumbing Water Pressure Drop |
psi |
15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Total Pressure Drop |
psi |
51 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A1 |
|
8.0713 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B1 |
|
1730.6300 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C1 |
|
233.4260 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A2 |
|
8.1402 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B2 |
|
1810.9400 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C2 |
|
244.4850 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A |
|
8.0713 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B |
|
1730.6300 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C |
|
233.4260 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Boiling Pressure at Outlet Temp |
psi |
1.8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Boiling Pressure at Outlet Temp |
PA |
1.23E+04 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Return pressure multiple of boiling |
|
2.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Return pressure |
psi |
3.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Return pressure |
PA |
2.46E+04 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Inlet pressure |
psi |
54.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Inlet pressure |
PA |
3.75E+05 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Allowable inlet pressure |
psi |
100.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Allowable inlet pressure |
PA |
6.89E+05 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water thermal resistance per pole |
Watt/deg C |
5.50E+03 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 100% IACS Resistivity at 20C |
ohm-m |
1.72E-08 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| %IACS |
|
100% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Resistivity at 20C |
ohm-m |
1.72E-08 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Resistance per pole at 20C |
ohm |
5.49E-05 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Temp Coefficient of Resistivity |
per deg C |
0.0041 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Average Resisitivity |
ohm-m |
1.92E-08 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Resistance per pole at average temperature |
ohm |
6.11E-05 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Ohmic dissipation per pole |
Watt |
1.38E+04 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Ohmic dissipation per unit length |
kW/m |
0.45 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| #Coils in circuit |
|
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| # Interleaves per coil |
|
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Total # bus bar poles |
|
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Total ohmic dissipation, fraction of total coil +
bus bar |
|
0.05 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water delta_T |
deg C |
5.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Allowable delta_T |
deg C |
5.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cu temp coefficient of specific heat |
per deg C |
0.105 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cu 20C specific heat |
J/kg-degC |
393.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cu specific heat at avg temp |
J/kg-degC |
396.3875 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cu density |
kg/m3 |
8950 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cu heat capacity |
J/degC |
5.12E+05 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| delta_T/sec (LOCW) |
degC/sec |
0.03 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Total flow |
m3/s |
2.67E-03 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Total mass flow |
kg/s |
2.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Total bus bar resistance at 20C |
ohm |
1.10E-04 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Total bus bar resistance at average temperature |
ohm |
1.22E-04 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Max billet |
kg |
250 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Max length of single conductor section |
m |
5.9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|