| VS COIL | LOWER | LOWER | UPPER | UPPER | |
| N Turns | N-1 Turns | N Turns | N-1 Turns | ||
| Conductor pack width | m | 0.132 | 0.132 | 0.132 | 0.132 |
| Conductor pack height | m | 0.128 | 0.128 | 0.128 | 0.128 |
| Jacket OD | mm | 59.0 | 59.0 | 59.0 | 59.0 |
| Jacket thickness | mm | 2.0 | 2.0 | 2.0 | 2.0 |
| Insulation thickness | mm | 5.0 | 5.0 | 5.0 | 5.0 |
| Conductor OD | mm | 45.0 | 45.0 | 45.0 | 45.0 |
| Conductor ID | mm | 30.0 | 30.0 | 30.0 | 30.0 |
| Conductor length per turn | m | 47.1 | 47.1 | 36.3 | 36.3 |
| Feeder length per pole | m | 10.0 | 10.0 | 10.0 | 10.0 |
| #Sub-circuits | 4 | 3 | 4 | 3 | |
| #Turns per sub-circuit | 1 | 1 | 1 | 1 | |
| Total conductor length per sub-circuit | m | 67.1 | 67.1 | 56.3 | 56.3 |
| #Sub-circuits in series hydraulically | 1 | 1 | 1 | 1 | |
| #Sub-circuits in parallel hydraulically | 4 | 3 | 4 | 3 | |
| #Sub-circuits in series electrically | 4 | 3 | 4 | 3 | |
| #Sub-circuits in parallel electrically | 1 | 1 | 1 | 1 | |
| Base total current | Amp-turn rms | 35894 | 35894 | 35894 | 35894 |
| #Turns effective | 4 | 3 | 4 | 3 | |
| Per unit current | p.u. | 1.00 | 1.00 | 1.00 | 1.00 |
| Current per turn effective | Amp rms | 8974 | 11965 | 8974 | 11965 |
| Current per sub-circuit | Amp rms | 8974 | 11965 | 8974 | 11965 |
| Net series/parallel circuit resistance at 20C | mOhm | 5.237 | 3.927 | 4.393 | 3.295 |
| Flow velocity | m/s | 3.0 | 5.0 | 3.0 | 5.0 |
| Water Inlet Temperature | deg C | 100 | 100 | 100 | 100 |
| Coil delta_T | deg C | 21 | 20 | 18 | 17 |
| Total delta_T across hydraulic circuit | deg C | 31 | 29 | 28 | 26 |
| Maximum temperature | deg C | 121 | 120 | 118 | 117 |
| Net series/parallel circuit resistance at average resistivity | mOhm | 7.291 | 5.450 | 6.141 | 4.551 |
| Total ohmic dissipation | kW | 587 | 780 | 495 | 651 |
| Volumetric nuclear heating rate | watt/cc | 0.48 | 0.48 | 0.48 | 0.48 |
| Nuclear heated volume | m3 | 8.57E-01 | 8.57E-01 | 8.57E-01 | 8.57E-01 |
| Total nuclear heating | kW | 414 | 414 | 414 | 414 |
| Total heat load | kW | 1001 | 1194 | 909 | 1065 |
| Heat load per hydraulic circuit | kW | 250 | 398 | 227 | 355 |
| delta_T/sec (LOCW) | degC/sec | 1.2 | 1.9 | 1.3 | 2.0 |
| Total Pressure Drop | MPA | 0.24 | 0.43 | 0.22 | 0.38 |
| Boiling Pressure at Outlet Temp | MPA | 0.28 | 0.26 | 0.30 | 0.24 |
| Return pressure | MPA | 0.56 | 0.52 | 0.61 | 0.48 |
| Inlet pressure | MPA | 0.80 | 0.96 | 0.82 | 0.86 |
| Total Cu wetted surface to TCWS | m2 | 25 | 19 | 21 | 16 |
| Total water volume in TCWS | m3 | 0.19 | 0.14 | 0.16 | 0.12 |
| VS BUS BAR | |||||
| Conductor width | m | 0.0500 | 0.0500 | ||
| Conductor height | m | 0.1000 | 0.1000 | ||
| Cooling hole diameter | m | 0.0175 | 0.0175 | ||
| Current | Amp rms | 8974 | 8974 | ||
| Avg conductor length per pole | m | 47 | 47 | ||
| #Conductor in parallel electrically and hydraulically per pole | 2 | 2 | |||
| Resistance per pole at 20C | mOhm | 0.084 | 0.084 | ||
| Flow velocity | m/s | 1.2 | 1.2 | ||
| Flow per conductor | m3/s | 2.93E-04 | 2.93E-04 | ||
| Mass flow per conductor | kg/s | 0.29 | 0.29 | ||
| #Poles in series hydraulically | 1 | 1 | |||
| Hydraulic path delta_P | MPA | 0.04 | 0.04 | ||
| Return pressure | MPA | 0.02 | 0.02 | ||
| Inlet pressure | MPA | 0.17 | 0.17 | ||
| Water Inlet Temperature | deg C | 45 | 45 | ||
| Water delta_T | deg C | 3 | 3 | ||
| Resistance per pole at average temperature | mOhm | 0.094 | 0.094 | ||
| Ohmic dissipation per pole | kW | 8 | 8 | ||
| Ohmic dissipation per unit length | kW/m | 0.16 | 0.16 | ||
| Total # bus bar poles | 16 | 16 | |||
| Total ohmic dissipation, fraction of total coil + bus bar | 0.09 | 0.09 | |||
| Total flow | m3/s | 9.37E-03 | 9.37E-03 | ||
| Total mass flow | kg/s | 9.3 | 9.3 | ||
| Total bus bar resistance at 20C | ohm | 1.35E-03 | 1.35E-03 | ||
| Total bus bar resistance at average temperature | ohm | 1.50E-03 | 1.50E-03 | ||
| Total bus bar inductance | henry | 7.39E-05 | 7.39E-05 | ||
| TOTAL VS CIRCUIT | N Turns in UPPER & LOWER | N-1 Turns in UPPER & LOWER | |||
| Coil resistance (upper + lower) at operating temperature | ohm | 1.34E-02 | 1.01E-02 | ||
| Coil inductance (upper + lower anti-series) | henry | 1.22E-03 | 6.88E-04 | ||
| Bus bar resistance at operating temperature | ohm | 1.50E-03 | 1.50E-03 | ||
| Bus bar inductance | henry | 7.39E-05 | 7.39E-05 | ||
| Total circuit resistance at operating temperature | ohm | 1.49E-02 | 1.16E-02 | ||
| Total circuit inductance | henry | 1.30E-03 | 7.62E-04 | ||
| Rated voltage | Volt | 2400 | 2400 | ||
| WAVEFORM COMPONENTS | |||||
| Transient component | |||||
| I_max | Amp per turn | 60000 | 80000 | ||
| Amplitude | Amp | 7.44E+04 | 9.92E+04 | ||
| Tau_1 | sec | 0.304 | 0.304 | ||
| Tau_2 | sec | 0.016 | 0.016 | ||
| Peak current | Amp per turn | 60000 | 80000 | ||
| Period | Sec | 10 | 10 | ||
| Events per plasma | Events | 3 | 3 | ||
| Noise component | |||||
| RMS Current | Amp per turn | 2907 | 3876 | ||
| Peak Current | Amp per turn | 4111 | 5482 | ||
| Fraction of max voltage driving noise | 0.5 | 0.5 | |||
| Impedance Z | Ohm | 2.76E-01 | 2.07E-01 | ||
| Reactance X | Ohm | 2.75E-01 | 2.06E-01 | ||
| Frequency | Hz | 33.8 | 25.3 | ||
| Total Current | |||||
| Min plasma duration | sec | 200 | 200 | ||
| Base period | sec | 10 | 10 | ||
| I2T over base period | Amp2-sec | 8.05E+08 | 1.43E+09 | ||
| I_rms over base & consecutive periods | Amp per turn | 8974 | 11965 | ||
| I_rms over min plasma duration | Amp per turn | 2680 | 3728 | ||
| VS Power Supply | |||||
| Rated voltage | Volt | 2400 | 2400 | ||
| Equiv series resistance of cap bank | Ohm | 3.78E-03 | 3.78E-03 | ||
| Capacitor bank | Farad | 5.208 | 5.208 | ||
| Charger rated output power | Watt | 1.20E+06 | 1.20E+06 | ||
| Equiv series resistance of charger | Ohm | 0.766 | 0.766 | ||
| Charger rated current | Amp | 626 | 626 | ||
| Charger rated apparent power | Volt-amp | 1.50E+06 | 1.50E+06 | ||
| TOTAL VS SYSTEM | |||||
| Simultaneity factor | 1.00 | 1.00 | |||
| Total input active power | watt | 1.20E+06 | 1.20E+06 | ||
| Total input reactive power | volt-amp-reactive | 9.02E+05 | 9.02E+05 | ||
| Total input apparent power | volt-amp | 1.50E+06 | 1.50E+06 | ||
| Total ohmic + nuclear heat load from coils to TCWS | watt | 1.91E+06 | 2.26E+06 | ||
| Total mass flow to coils from TCWS | kg/s | 15.4 | 19.3 | ||
| TCWS Return pressure (minimum) | MPA | 0.56 | 0.52 | ||
| Total Coil Pressure Drop to TCWS (max of upper and lower coils) | MPA | 0.24 | 0.43 | ||
| TCWS Inlet pressure (minimum) | MPA | 0.80 | 0.96 | ||
| TCWS Water Inlet Temperature | deg C | 100 | 100 | ||
| TCWS Water Outlet Temperature (max of upper and lower coils) | deg C | 121 | 120 | ||
| Total Cu wetted surface to TCWS | m2 | 47 | 35 | ||
| Total water volume in TCWS | m3 | 0.35 | 0.26 | ||
| Total heat load from bus bar to CCWS | watt | 1.21E+05 | 1.21E+05 | ||
| Total mass flow to bus bar from CCWS | kg/s | 9 | 9 | ||