VS COIL |
|
LOWER |
LOWER |
UPPER |
UPPER |
|
|
N Turns |
N-1 Turns |
N Turns |
N-1 Turns |
Conductor pack width |
m |
0.132 |
0.132 |
0.132 |
0.132 |
Conductor pack height |
m |
0.128 |
0.128 |
0.128 |
0.128 |
Jacket OD |
mm |
59.0 |
59.0 |
59.0 |
59.0 |
Jacket thickness |
mm |
2.0 |
2.0 |
2.0 |
2.0 |
Insulation thickness |
mm |
5.0 |
5.0 |
5.0 |
5.0 |
Conductor OD |
mm |
45.0 |
45.0 |
45.0 |
45.0 |
Conductor ID |
mm |
30.0 |
30.0 |
30.0 |
30.0 |
Conductor length per turn |
m |
47.1 |
47.1 |
36.3 |
36.3 |
Feeder length per pole |
m |
10.0 |
10.0 |
10.0 |
10.0 |
#Sub-circuits |
|
4 |
3 |
4 |
3 |
#Turns per sub-circuit |
|
1 |
1 |
1 |
1 |
Total conductor length per sub-circuit |
m |
67.1 |
67.1 |
56.3 |
56.3 |
#Sub-circuits in series hydraulically |
|
1 |
1 |
1 |
1 |
#Sub-circuits in parallel hydraulically |
|
4 |
3 |
4 |
3 |
#Sub-circuits in series electrically |
|
4 |
3 |
4 |
3 |
#Sub-circuits in parallel electrically |
|
1 |
1 |
1 |
1 |
Base total current |
Amp-turn rms |
35894 |
35894 |
35894 |
35894 |
#Turns effective |
|
4 |
3 |
4 |
3 |
Per unit current |
p.u. |
1.00 |
1.00 |
1.00 |
1.00 |
Current per turn effective |
Amp rms |
8974 |
11965 |
8974 |
11965 |
Current per sub-circuit |
Amp rms |
8974 |
11965 |
8974 |
11965 |
Net series/parallel circuit resistance at 20C |
mOhm |
5.237 |
3.927 |
4.393 |
3.295 |
Flow velocity |
m/s |
3.0 |
5.0 |
3.0 |
5.0 |
Water Inlet Temperature |
deg C |
100 |
100 |
100 |
100 |
Coil delta_T |
deg C |
21 |
20 |
18 |
17 |
Total delta_T across hydraulic circuit |
deg C |
31 |
29 |
28 |
26 |
Maximum temperature |
deg C |
121 |
120 |
118 |
117 |
Net series/parallel circuit resistance at average
resistivity |
mOhm |
7.291 |
5.450 |
6.141 |
4.551 |
Total ohmic dissipation |
kW |
587 |
780 |
495 |
651 |
Volumetric nuclear heating rate |
watt/cc |
0.48 |
0.48 |
0.48 |
0.48 |
Nuclear heated volume |
m3 |
8.57E-01 |
8.57E-01 |
8.57E-01 |
8.57E-01 |
Total nuclear heating |
kW |
414 |
414 |
414 |
414 |
Total heat load |
kW |
1001 |
1194 |
909 |
1065 |
Heat load per hydraulic circuit |
kW |
250 |
398 |
227 |
355 |
delta_T/sec (LOCW) |
degC/sec |
1.2 |
1.9 |
1.3 |
2.0 |
Total Pressure Drop |
MPA |
0.24 |
0.43 |
0.22 |
0.38 |
Boiling Pressure at Outlet Temp |
MPA |
0.28 |
0.26 |
0.30 |
0.24 |
Return pressure |
MPA |
0.56 |
0.52 |
0.61 |
0.48 |
Inlet pressure |
MPA |
0.80 |
0.96 |
0.82 |
0.86 |
Total Cu wetted surface to TCWS |
m2 |
25 |
19 |
21 |
16 |
Total water volume in TCWS |
m3 |
0.19 |
0.14 |
0.16 |
0.12 |
VS BUS BAR |
|
|
|
|
|
Conductor width |
m |
0.0500 |
0.0500 |
|
|
Conductor height |
m |
0.1000 |
0.1000 |
|
|
Cooling hole diameter |
m |
0.0175 |
0.0175 |
|
|
Current |
Amp rms |
8974 |
8974 |
|
|
Avg conductor length per pole |
m |
47 |
47 |
|
|
#Conductor in parallel electrically and
hydraulically per pole |
|
2 |
2 |
|
|
Resistance per pole at 20C |
mOhm |
0.084 |
0.084 |
|
|
Flow velocity |
m/s |
1.2 |
1.2 |
|
|
Flow per conductor |
m3/s |
2.93E-04 |
2.93E-04 |
|
|
Mass flow per conductor |
kg/s |
0.29 |
0.29 |
|
|
#Poles in series hydraulically |
|
1 |
1 |
|
|
Hydraulic path delta_P |
MPA |
0.04 |
0.04 |
|
|
Return pressure |
MPA |
0.02 |
0.02 |
|
|
Inlet pressure |
MPA |
0.17 |
0.17 |
|
|
Water Inlet Temperature |
deg C |
45 |
45 |
|
|
Water delta_T |
deg C |
3 |
3 |
|
|
Resistance per pole at average temperature |
mOhm |
0.094 |
0.094 |
|
|
Ohmic dissipation per pole |
kW |
8 |
8 |
|
|
Ohmic dissipation per unit length |
kW/m |
0.16 |
0.16 |
|
|
Total # bus bar poles |
|
16 |
16 |
|
|
Total ohmic dissipation, fraction of total coil +
bus bar |
|
0.09 |
0.09 |
|
|
Total flow |
m3/s |
9.37E-03 |
9.37E-03 |
|
|
Total mass flow |
kg/s |
9.3 |
9.3 |
|
|
Total bus bar resistance at 20C |
ohm |
1.35E-03 |
1.35E-03 |
|
|
Total bus bar resistance at average temperature |
ohm |
1.50E-03 |
1.50E-03 |
|
|
Total bus bar inductance |
henry |
7.39E-05 |
7.39E-05 |
|
|
TOTAL VS CIRCUIT |
|
N Turns in UPPER & LOWER |
N-1 Turns in UPPER & LOWER |
|
|
Coil resistance (upper + lower) at operating
temperature |
ohm |
1.34E-02 |
1.01E-02 |
|
|
Coil inductance (upper + lower anti-series) |
henry |
1.22E-03 |
6.88E-04 |
|
|
Bus bar resistance at operating temperature |
ohm |
1.50E-03 |
1.50E-03 |
|
|
Bus bar inductance |
henry |
7.39E-05 |
7.39E-05 |
|
|
Total circuit resistance at operating temperature |
ohm |
1.49E-02 |
1.16E-02 |
|
|
Total circuit inductance |
henry |
1.30E-03 |
7.62E-04 |
|
|
Rated voltage |
Volt |
2400 |
2400 |
|
|
WAVEFORM COMPONENTS |
|
|
|
|
|
Transient component |
|
|
|
|
|
I_max |
Amp per turn |
60000 |
80000 |
|
|
Amplitude |
Amp |
7.44E+04 |
9.92E+04 |
|
|
Tau_1 |
sec |
0.304 |
0.304 |
|
|
Tau_2 |
sec |
0.016 |
0.016 |
|
|
Peak current |
Amp per turn |
60000 |
80000 |
|
|
Period |
Sec |
10 |
10 |
|
|
Events per plasma |
Events |
3 |
3 |
|
|
Noise component |
|
|
|
|
|
RMS Current |
Amp per turn |
2907 |
3876 |
|
|
Peak Current |
Amp per turn |
4111 |
5482 |
|
|
Fraction of max voltage driving noise |
|
0.5 |
0.5 |
|
|
Impedance Z |
Ohm |
2.76E-01 |
2.07E-01 |
|
|
Reactance X |
Ohm |
2.75E-01 |
2.06E-01 |
|
|
Frequency |
Hz |
33.8 |
25.3 |
|
|
Total Current |
|
|
|
|
|
Min plasma duration |
sec |
200 |
200 |
|
|
Base period |
sec |
10 |
10 |
|
|
I2T over base period |
Amp2-sec |
8.05E+08 |
1.43E+09 |
|
|
I_rms over base & consecutive periods |
Amp per turn |
8974 |
11965 |
|
|
I_rms over min plasma duration |
Amp per turn |
2680 |
3728 |
|
|
VS Power Supply |
|
|
|
|
|
Rated voltage |
Volt |
2400 |
2400 |
|
|
Equiv series resistance of cap bank |
Ohm |
3.78E-03 |
3.78E-03 |
|
|
Capacitor bank |
Farad |
5.208 |
5.208 |
|
|
Charger rated output power |
Watt |
1.20E+06 |
1.20E+06 |
|
|
Equiv series resistance of charger |
Ohm |
0.766 |
0.766 |
|
|
Charger rated current |
Amp |
626 |
626 |
|
|
Charger rated apparent power |
Volt-amp |
1.50E+06 |
1.50E+06 |
|
|
TOTAL VS SYSTEM |
|
|
|
|
|
Simultaneity factor |
|
1.00 |
1.00 |
|
|
Total input active power |
watt |
1.20E+06 |
1.20E+06 |
|
|
Total input reactive power |
volt-amp-reactive |
9.02E+05 |
9.02E+05 |
|
|
Total input apparent power |
volt-amp |
1.50E+06 |
1.50E+06 |
|
|
Total ohmic + nuclear heat load from coils to TCWS |
watt |
1.91E+06 |
2.26E+06 |
|
|
Total mass flow to coils from TCWS |
kg/s |
15.4 |
19.3 |
|
|
TCWS Return pressure (minimum) |
MPA |
0.56 |
0.52 |
|
|
Total Coil Pressure Drop to TCWS (max of upper and
lower coils) |
MPA |
0.24 |
0.43 |
|
|
TCWS Inlet pressure (minimum) |
MPA |
0.80 |
0.96 |
|
|
TCWS Water Inlet Temperature |
deg C |
100 |
100 |
|
|
TCWS Water Outlet Temperature (max of upper and
lower coils) |
deg C |
121 |
120 |
|
|
Total Cu wetted surface to TCWS |
m2 |
47 |
35 |
|
|
Total water volume in TCWS |
m3 |
0.35 |
0.26 |
|
|
Total heat load from bus bar to CCWS |
watt |
1.21E+05 |
1.21E+05 |
|
|
Total mass flow to bus bar from CCWS |
kg/s |
9 |
9 |
|
|
|
|
|
|
|
|