TF OH (Inner) OH (Outer) OH PF1A PF1B PF1C
Turn insulation glass tape thickness mm 0.152     0.152 0.127 0.127 0.127
Turn insulation glass tape compression   0.11     0.1 0.070 0.070 0.070
Turn insulation #half lapped glass tape layers   3     3 2 2 2
Turn insulation kapton tape thickness mm       0.051 0.1 0.1 0.1
Turn insulation kapton adhesive thickness mm       0.015 0.02 0.02 0.02
Turn insulation #half lapped kapton tape layers         3 2 2 2
Turn insulation build mm 0.813     1.219 0.7 0.7 0.7
Ground insulation glass tape thickness mm 0.254 0.254 0.254   0.2 0.3 0.3
Ground insulation glass tape compression   0.075 0.1 0.1   0.1 0.1 0.1
Ground insulation #half lapped glass tape layers   12 6 6   5 6 4
Ground insulation build mm 5.639 2.743 2.743   2.2 2.8 1.8
Ground + Turn insulation build mm 6.452 3.962 3.962   2.9 3.5 2.6
Terminal-terminal voltage kV 1.013     6 2 2 2
Turn voltage stress factor   1.00     0.50 0.50 1.00 1.00
Hipot voltage kV 7.0     17.2 13 13 13
Max turn-to-turn voltage kV 1.013     3 1 2 2
Max turn-turn stress kV/mm 0.6     1 1 1 1
Turn insulation dielectric strength constant kv/mm^0.5 50     55 50 50 50
Turn-turn dielectric strength kV 64     86 61 61 61
Turn insulation safety factor   63     28 60 30 30
Turn insulation safety factor (hipot)   21            
Max turn-to-ground stress, nominal kV/mm 0.5 1.9 2.0   2 2 2
Max turn-to-ground stress, hipot kV/mm 1.1 4.1 4.3   4 4 5
Ground insulation dielectric strength constant kv/mm^0.5 50 50 50   50.0 50.0 50.0
Ground insulation dielectric strength kV 127 100 100   85 94 80
Ground insulation safety factor   42 12 16   21 23 20
Ground insulation safety factor (hipot)   18 6 6   7 7 6
TF OH (Inner) OH (Outer) OH PF1A PF1B PF1C
Turn insulation glass tape thickness mil 6.0     6.0 5.0 5.0 5.0
Turn insulation glass tape compression   0.11     0.1 0.070 0.070 0.070
Turn insulation #half lapped glass tape layers   3     3 2 2 2
Turn insulation kapton tape thickness mil       2.0 2.0 2.0 2.0
Turn insulation kapton adhesive thickness mil       0.6 0.60 0.60 0.60
Turn insulation #half lapped kapton tape layers         3 2 2 2
Turn insulation build mil 32.0     48.0 29.0 29.0 29.0
Ground insulation glass tape thickness mil 10.0 10.0 10.0   9.8 10.0 10.0
Ground insulation glass tape compression   0.1 0.1 0.1   0.1 0.1 0.1
Ground insulation #half lapped glass tape layers   12 6 6   5 6 4
Ground insulation build mil 222.0 108.0 108.0   86.0 110.0 72.0
Ground + Turn insulation build mil 254.0 156.0 156.0   115.0 139.0 101.0
Terminal-terminal voltage volt 1013     6077 2026 2026 2026
Turn voltage stress factor   1.00     0.50 0.50 1.00 1.00
Hipot voltage volt 7026     17154 13103 13103 13103
Max turn-to-turn voltage volt 1013     3039 1013 2026 2026
Max turn-turn stress volt/mil 16     32 15 31 30
Turn insulation dielectric strength constant kv/mil^0.5 8     9 8 8 8
Turn-turn dielectric strength kV 64     86 61 61 61
Turn insulation safety factor kV 63     28 60 30 30
Turn insulation safety factor (hipot)   21            
Max turn-to-ground stress, nominal volt/mil 12 49 52   53 44 60
Max turn-to-ground stress, hipot volt/mil 28 105 110   114 94 130
Ground insulation dielectric strength constant kv/mil^0.5 8.0 8.0 8.0   8.0 8.0 8.0
Ground insulation dielectric strength kV 127 100 100   85 94 80
Ground insulation safety factor   42 12 12   21 23 20
Ground insulation safety factor (hipot)   18 6 6   7 7 6