Front Page
(Redirected from Main Page)
New LTX personnel should look at these pages for information about establishing the necessary accounts, permissions, etc.
Recommendations for wiki formatting and other helpful wiki-editing notes are available on the LTX Wiki Editing page.
Administration/Conventions
- Control Room Use & Access
- LTX Wiki Editing
- Measurement conventions
- Grant Acknowledgement
- LTX-β Hazard/Impact Breakdown & Categorization (SBS Numbers)
Maintenance/Hardware
Computer/Software Use
Procedures
LTX Operation
- LTX-β general operations C-LTX-beta-OP-G-01 Rev3 (effective 2025)
- Neutral beam operation C-LTX-B-OP-NB-01 Rev2 (updated 2024)
- Old LTX operations OP-LTX-001 (updated June 15th, 2015) - deprecated
- Field coil power supply operation - to be uploaded
- Thomson scattering laser safety - LSOP-22 Rev7 (updated September 17, 2018)
- Neutral beam daily shot log
- C-LTX-B-AP-NB-1 LTX-B Neutral Beam Power Supply Access Procedure]
- C-LTX-B-AP-LASR-1 LTX-B Thomson Scattering Laser Capacitor Bank Access Procedure
- C-LTX-B-IP-SEP-3996 Dock the Sample Exposure Probe (SEP) to the Argon Glove Box and transfer a quantity (< 680 mg)
- C-LTX-B-OP-LiDCL-1 Cleaning of Lithium Dropper in C-128 and Loading of Dropper in L245
- C-LTX-B-OP-GDC-1 LTX-ß Glow Discharge Cleaning (L210)
- C-LTX-B-AP-ECH-1 X Band ECH System Access Procedure
- C-LTX-B-ISTP-2 LTX-ß Neutral Beam Interlock Safety Test Procedure
- C-LTX-B-ISTP-1 LTX-B Integrated Safety Test Procedure
- C-LTX-AP-ECH-2 X Band ECH Equipment Testing Procedure
LTX Maintenance/Testing
- Field coil power supply (ESAT) access - to be uploaded
- Field coil power supply (L210) access - to be uploaded
- Ohmic heating power supply access - to be uploaded
- Thomson scattering cap bank access OP-CDX-010 (updated April 7th, 2017)
- LTX-β safety system testing - in progress
- Neutral beam power supply access - in progress
- Neutral beam safety interlock testing (ISTP) - in progress
- LTX-β TF Coil Inductive Hipot Testing - C-LTX-B-TP-TFHP-01 (updated July 10, 2019)
Offline Experiments
- C-OP-SA-01 - Loading and disposal of samples for surface analysis (Li foil XPS Scans using Thermo K-Alpha at IAC Princeton) (update March 16th, 2017)
- C-OP-SA-02 - Transferring Lithium Foil into and out of the Glove box in L-245 from the Lithium cabinet in L-245.
- C-LTX-IP-3996 - Docking SEP to the Argon Glove Box.
Diagnostics
Magnetic
Local Sensors/Arrays
Areal Mean Sensors
Optical/Spectroscopy
- Thomson scattering
- ChERS
- X-ray spectroscopy
- Reflectometry
- Interferometry
- Filterscopes
- Vacuum UV spectroscopy
- Toroidal and poloidal photodiode arrays
Physical Probes
- HFS edge probes
- LFS SOL probes
- Single Langmuir Probe analysis suite
- Fluctuation Probe
- Sample Exposure Probe (SEP)
- Retarding Field Energy Analyzer (RFEA)
Operational Diagnostics
Supporting Systems
Plasma generation
- Equilibrium field coils
- ECH
- Fueling systems
Chamber systems
- Vacuum vessel
- Vessel cooling water (Mokon)
- Limiting shells
- Pumping systems
- Lithium application
Data acquisition and access
- Integrators
- Digitizers
- MDSplus trees
- Analysis codes
- TRANSP
- Equilibrium Reconstruction (in dev)
- WebTools
Other Equipment
- Water conductivity meter
- Crown XLS 2502 audio amplifier
- Mirnov calibration Helmholtz coil
- Epowersys CDG7000 surge tester
PCS
Official Agreement to use GA PCS framework for LTX-beta:
Hardware connection diagrams:
Signal validation:
LEMO channels to be terminated (WIP)
PCS related triggers
- RCIMIII external input 1 gets trigger from Jorway 2 output 7, at t=0 [s] (untested) (updated this information on 29 October 2024)
Records
- Cable assembly 64 ch analog pass-through harness rev 1 File:1861490 r1.pdf
- Cable assembly 64 ch analog pass-through panel rev 1 File:1861491 r1.pdf
- Cable assembly 64 ch analog pass-through panel rev 2 File:1861491 r2.pdf
Experiment Documentation
LTX Experiments
Proposed
Ongoing
Completed
- January 2020 Notable
- March 2019 Notable
- Flat Te? (2015)
Supporting Experiments
Calibrations
Publications
The PPPL Publications Submission Form for patent clearance can be found here or here