Thermocouples
Ex-Vessel
Coils
Center Stack
In-Vessel
Shells
Neutral Beam Tank Getter
Mounted to the back (LTX side) of the neutral beam tank baffle to measure getter temperature. Roughly centered in port A-B (φ=22.5°).
| Thermocouple | Feedthrough | |||
|---|---|---|---|---|
| ID |
Location |
Port |
Mil-C Connector |
TC Connector |
| D1 |
Bottom (1.75" up) |
Section B-C |
Left 2.75" CF |
Right |
| D2 |
Middle (5.0" up) |
Section B-C |
Left 2.75" CF |
Bottom |
| D3 |
Upper (8.5" up) |
Section B-C |
Left 2.75" CF |
Left |
Center Stack
Mounted under the heat shield in section P-A (φ=0°).
| Thermocouple | Feedthrough | |||
|---|---|---|---|---|
| ID |
Location |
Port |
Mil-C Connector |
TC Connector |
| CS1 |
Bottom |
Section B-C |
Left 2.75" CF |
Top |
| CS2 |
Lower |
Section B-C |
Right 2.75" CF |
Right |
| CS3 |
Middle |
Section B-C |
Right 2.75" CF |
Bottom |
| CS4 |
Upper |
Section B-C |
Right 2.75" CF |
Left |
| CS5 |
Top |
Section B-C |
Right 2.75" CF |
Top |
Acquisition
64 total channels, 32 on back of shells (8 on each), rest on centerstack and coils. Shell thermocouple feedthrough are on top and bottom one bay on either side of heater feedthroughs. All connections go to breakout boxes on cable trays north and south of the vessel, then to digitizer in L209 racks. Data acquired on LTX-β in control room via LabView interface, which can display, plot, and store the data.
Related Pages
Diagnostics
Magnetics (Local): Reentrant array | Toroidal array | Saddle coils | Shell eddy sensors
Magnetics (Areal): Poloidal flux loops | Loop voltage | Diamagnetic loop | IP Rogowski
Spectroscopy: Thomson scattering | ChERS | X-ray spectroscopy | Spectrometry | Vacuum UV spectroscopy
Microwaves: Reflectometry | Interferometry
Physical Probes: HFS edge probes | LFS SOL probes | RFEA
Operational Diagnostics: Ion gauges | Coil current monitors | Thermocouples | RTDs